{"product_id":"alcohol-o2-controller-sonda-o2-doppio-canale-lab-grade","title":"ALCOHOL O2 - CONTROLLER SONDA O2 DOPPIO CANALE (LAB GRADE)","description":"\u003cp id=\"p-rc_e959d388bc6b9d86-146\" data-path-to-node=\"2\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eL'Alcohol O2 Dual Channel Lab Grade è un controller per sonda Lambda ad alta velocità e precisione, progettato esclusivamente per l'uso con sonde Lambda NTK (le quali richiedono la calibrazione in aria libera). \u003cspan class=\"citation-249\"\u003eFornisce letture di miscele aria\/carburante estremamente grasse, a partire da \u003c\/span\u003e\u003cspan class=\"citation-249\"\u003e0,28 Lambda\u003c\/span\u003e\u003cspan class=\"citation-249\"\u003e (\u003c\/span\u003e\u003cspan class=\"citation-249\"\u003e1,80 AFR Alcohol\u003c\/span\u003e\u003cspan class=\"citation-249 citation-end-249\"\u003e).\u003csup data-turn-source-index=\"1\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"citation-249 citation-end-249\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan class=\"citation-248\"\u003eQuando utilizzato con una centralina FuelTech PowerFT (\u003c\/span\u003e\u003cspan class=\"citation-248\"\u003eFT450, FT550, FT550LITE o FT600\u003c\/span\u003e\u003cspan class=\"citation-248\"\u003e), il controller Alcohol O2 trasmette i dati alla ECU tramite comunicazione \u003c\/span\u003e\u003cspan class=\"citation-248\"\u003eCAN bus\u003c\/span\u003e\u003cspan class=\"citation-248 citation-end-248\"\u003e.\u003csup data-turn-source-index=\"2\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e Per il collegamento a sistemi di acquisizione dati esterni alla linea FuelTech, l'Alcohol O2 dispone di un'uscita analogica 0-5V.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,0\"\u003eInclusi:\u003c\/b\u003e Kit di montaggio e Kit promozionale. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cb data-index-in-node=\"46\" data-path-to-node=\"4,0\"\u003eNota:\u003c\/b\u003e Cablaggio venduto separatamente.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"6\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eDESCRIZIONE PRODOTTO\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli id=\"p-rc_e959d388bc6b9d86-148\" data-path-to-node=\"7,0,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan class=\"citation-247\"\u003eStrumento di alta precisione e velocità per la gestione di \u003c\/span\u003e\u003cspan class=\"citation-247\"\u003esonde Lambda NTK\u003c\/span\u003e\u003cspan class=\"citation-247 citation-end-247\"\u003e.\u003csup data-turn-source-index=\"3\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"p-rc_e959d388bc6b9d86-149\" data-path-to-node=\"7,1,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan class=\"citation-246\"\u003eLetture di miscele aria\/carburante estremamente grasse: da \u003c\/span\u003e\u003cspan class=\"citation-246\"\u003e0,28 Lambda\u003c\/span\u003e\u003cspan class=\"citation-246\"\u003e (\u003c\/span\u003e\u003cspan class=\"citation-246\"\u003e1,80 AFR Alcohol\u003c\/span\u003e\u003cspan class=\"citation-246 citation-end-246\"\u003e).\u003csup data-turn-source-index=\"4\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-path-to-node=\"7,2,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eCalibrazione in aria libera (\u003ci data-index-in-node=\"29\" data-path-to-node=\"7,2,0\"\u003efree air calibration\u003c\/i\u003e) richiesta dal sensore.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"p-rc_e959d388bc6b9d86-150\" data-path-to-node=\"7,3,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan class=\"citation-245\"\u003eUtilizza sonde O2 speciali provenienti dai laboratori \u003c\/span\u003e\u003cspan class=\"citation-245\"\u003eNTK\u003c\/span\u003e\u003cspan class=\"citation-245 citation-end-245\"\u003e.\u003csup data-turn-source-index=\"5\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"p-rc_e959d388bc6b9d86-151\" data-path-to-node=\"7,4,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan class=\"citation-244\"\u003eComunicazione \u003c\/span\u003e\u003cspan class=\"citation-244\"\u003eCAN bus\u003c\/span\u003e\u003cspan class=\"citation-244 citation-end-244\"\u003e con FT600 \/ FT550 \/ FT500 \/ FT500LITE \/ FT450.\u003csup data-turn-source-index=\"6\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"p-rc_e959d388bc6b9d86-152\" data-path-to-node=\"7,5,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan class=\"citation-243 citation-end-243\" style=\"color: rgb(0, 0, 0);\"\u003eUscite analogiche per il collegamento con FT600 \/ FT550 \/ FT500 \/ FT500LITE \/ FT450, PRO24 o altri sistemi di acquisizione dati.\u003cbr\u003e\u003cbr\u003e\u003csup data-turn-source-index=\"7\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"9\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eCONTENUTO DELLA CONFEZIONE\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-path-to-node=\"10,0,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e(1) Alcohol O2 - Doppio Canale.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-path-to-node=\"10,1,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e(1) Guida all'installazione e al funzionamento.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-path-to-node=\"10,2,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e(1) Cablaggio a fili liberi per Alcohol O2 Doppio Canale da 8ft \/ 2,4m (opzionale).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"p-rc_e959d388bc6b9d86-153\" data-path-to-node=\"10,3,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan class=\"citation-242 citation-end-242\" style=\"color: rgb(0, 0, 0);\"\u003e(1) Kit di montaggio (4 supporti in gomma, 4 rondelle e 4 dadi da ¼”).\u003csup data-turn-source-index=\"8\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"p-rc_e959d388bc6b9d86-154\" data-path-to-node=\"10,4,0\" style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan class=\"citation-241 citation-end-241\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e(1) Kit promozionale (include una penna e un adesivo FuelTech in fibra di carbonio nera).\u003c\/span\u003e\u003csup data-turn-source-index=\"9\" class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan class=\"citation-241 citation-end-241\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: rgb(255, 5, 5);\"\u003e\u003cstrong\u003eATTENZIONE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(255, 5, 5);\"\u003eTutti gli articoli GMC Racing che comportano degli aumenti di potenza superiori a quelle previste dal codice stradale del paese dell’utente, sono destinati esclusivamente a uso competitivo. \u003cbr\u003eGMC Racing declina ogni responsabilità per qualsiasi uso del prodotto contrario alle norme nazionali.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GMC RACING ","offers":[{"title":"Senza cablaggio \/ Senza sonda Lambda","offer_id":56867721150795,"sku":"3010003398","price":1218.78,"currency_code":"EUR","in_stock":true},{"title":"Senza cablaggio \/ Con sonda Lambda","offer_id":56867721183563,"sku":"3010003398","price":1218.78,"currency_code":"EUR","in_stock":true},{"title":"Con cablaggio a fili liberi da 8ft (2.4m) \/ Senza sonda Lambda","offer_id":56867721216331,"sku":"3010003398","price":1218.78,"currency_code":"EUR","in_stock":true},{"title":"Con cablaggio a fili liberi da 8ft (2.4m) \/ Con sonda Lambda","offer_id":56867721249099,"sku":"3010003398","price":1218.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/7965\/4731\/files\/FuelTech-Dual-Channel-Alcohol-Wideband-O2-Controller_1024x1024_jpg.webp?v=1774275354","url":"https:\/\/shop.gmcracing.com\/products\/alcohol-o2-controller-sonda-o2-doppio-canale-lab-grade","provider":"GMC RACING ","version":"1.0","type":"link"}